It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer.
Product Features:
- Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle
- Tests like D Dimer performed using Immuno-turbidimetry principle
- Interactive touch screen interface
- Clotting Graph provides details of the clotting testCuvette and reagent management software
- Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors
- Temperature stability at 37 degree C to perform the tests.
- Low Reagent Consumption
- USB Connectivity
- CE mark
Product Applications:
- ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT
- It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII
- It is used as Standby to bigger systems, in accredited centres
- It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc
Technical Specification
Key Specifications:
- Single channel semi-automated hemostasis system
- It can analyze 1 test at a time
- Sample id can be 14 digits alphanumeric, with progressive id or custom id options
- It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option
- Optically detects and automatically moves to the next assay steps and auto starts the measurements
Tests principles:
- Clotting (scattered light at 640nm)
- Immuno-turbidimetric (turbidimetry at 800nm)
- Dimensions / Weight:
- Dimension : 216 x 205 x 75 mm
- Weight : ~1 kg
- Environmental requirements:
- Operating Temperature : 17-32°C
- Humidity: Max. 80% Relative Humidity, non-condensing
- Power:
- Power Supply : 100-240 VAC and 50/60 Hz
- Power Consumption : 45 Watts
- In-Rush Power : 150 VA or less
- Calibrations:
- Up to 6 calibration levels per assay
- Storage of the active calibration curve
- Quality Controls:
- Up to 12 different control total can be assigned to any given assay
- Automatic Levey-Jennings plotting
- Automatic statistics calculation
- Storage of Quality Control results
- Stored Results:
- Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations
- Up to 1000 results for QC determinations
- Up to 1000 results for patients
- New results automatically replace the oldest results of the appropriate category past the maximum storage allowance
- Reaction curves are exclusively stored on the external USB pen drive.
- Regular backup and file purging is recommended from the USB pen drive to insure rapid operations.
- USB pen drive, FAT32 formatted