Features
Tissue Harmonic Imaging : Yes
Spatial Compounding(=CrossXbeam) : No
Speckle Reduction (=SRI) : Yes
Auto Image Opt(B mode) : Yes
Auto Image Opt(Doppler) : Yes
Write Zoom : No
Triplex Mode : Yes
Needle Enhancement or Needle Recognition : No
Auto NT Measurement (=Sono NT): No
Auto Follicle 2D Measurement : No
Auto Follicle 3D Measurement : No
Auto IMT : Yes
Auto IMT (Real Time) : No
Automated B/M/D Measurement : Yes
Automated LH Measurement(Automated Function Imaging(AFI), Cardiac Motion Quantification(CMQ), or Auto EF(Ejection Fraction) : Yes
Live Dual (B/BC) Mode : Yes
SmartExam or Scan Assistant : No
Fusion : No
Raw Data File : Yes
Flexible Report : Yes
Barcode Reader : No
Gel Warmer : No
Transducers
Convex (1~6Mhz) : Yes
Convex (2~9Mhz) : No
Single Crystal Convex (1~6Mhz) : No
Single Crystal Convex (2~9Mhz) : No
2D Arrary 3D Convex (1~6Mhz) : No
Micro Convex (5~8Mhz) : No
Single Crystal Endocavity_Straight Type (3~10Mhz) : No
Endocavity_Curved Type (5~8Mhz) : No
3D Convex (2~6Mhz) : No
3D Convex Light Weight (2~7Mhz) : No
3D Endocavity (3~10Mhz) : No
3D Micro Convex (3~9Mhz) : No
3D Linear (4~18Mhz) : No
Linear (>14Mhz) : No
Linear (3~12Mhz) : Yes
Linear (<9Mhz) : Yes
Single Crystal Linear (>14Mhz) : No
Single Crystal Linear (3~12Mhz) : No
Single Crystal Linear (<9Mhz) : No
Linear 50mm : No
Linear 25mm : No
Hockey stick (<13Mhz) : No
Hockey stick (>13Mhz) : No
T or L shape Intra Operative : Yes
Phased Array_Adult (1~5Mhz) : Yes
Single Crystal Phased Array_Adult (1~5Mhz) : No
2D Arrary 3D Phased Array (1~5Mhz) : No
Phased Array_Pediatric (3~8hz) : Yes
Single Crystal Phased Array_Pediatric (3~8hz) : No
Phased Array_Neonate (4~12Mhz) : Yes
ICE (Intracardiac Echo Cardiography) : Yes
TEE_Adult (3-7Mhz) : Yes
TEE_Pediatric (3~7Mhz) :
2D Array 3D TEE (2~7Mhz) : No
Pencil CW (2Mhz): Yes
Pencil CW (5 or 6Mhz) : Yes
Imaging Modes
2D, M mode : Yes
M-color Flow Mode : Yes
Anatomical M-mode : Yes
Trapezoidal Mode : No
Color, Power Angio, Pulse Wave Doppler : Yes
Bi-directional Power (=HD FLOW) : No
SCW Doppler : Yes
Tissue Doppler(Velocity) Imaging : Yes
Freehand 3D : No
Live 3/4D OB/GYN : No
HD Live : No
STIC (Spatio-Temporal Image Correlation) : No
Live 3D Echo : No
Stress Echo : Yes(Option)
Strain and Strain Rate (Cardiac) : Yes(Option)
B Flow : Yes(Option)
Panoramic Imaging (=Logiq view) : No
Contrast Imaging – Cardiac : Yes(Option)
Contrast Imaging – General Imaging : Yes(Option)
Strain-based Elastography : No
Shear Wave Elastography : No
Applications
Abdominal : Yes
Women’s Health Care (GYN & Breast) : Yes
OB : Yes
Fetal Echo : Yes
Vascular : Yes
TCD(Transcranial) : Yes
Small Parts (Breast, Thyroid, Testis…) : Yes
MSK/Anesthesiology : Yes
Pediatrics : Yes
Urology (Renal, Prostate…) : No
Echocardiography_Adult : Yes
Interventional Cardiology : Yes
Echocardiography_Pediatric : Yes
Echocardiography_Neonate : Yes
Stress Echocardiography : Yes
Transesophageal Echo_Adult : Yes
Transesophageal Echo_Pediatric : Yes
Internal Medicine w/ Shared Service : Yes
Surgury : Yes
Interventional Radiology : Yes
Contrast Imaging _ General Imaging (Low MI) : No
Contrast Imaging _ Cardiac (High or Low MI) : No
Bowel Imaging : No
Strain Elastography : No
Shear Wave Elastography : No
Specification
System Overview
Year Launched : 2008
Estimated Market Price ($) : High
Monitor (inch) : 15″LCD
Tilt/Rotate Adjustable Monitor : No
Monitor Resolution : 1600*1200
Image Size Resolution : 800*600
Touch Screen (Inch) : No
Trackball or Trackpad : Trackball
CP Back-Lighting : Yes
Weight : 11lbs(5kg)
Probe Ports : 1
Battery : O(up to 1 hr)
Boot-Up Time :
Sleep Mode (Quick Start):
Maximum Depth of Field : 30cm
Minimum Depth of Field : 0-2cm
Cart (HCU) : Yes(Option)
Independent Steer & Lockable Wheels : Yes
Connectivity
DICOM 3.0 : Yes
DICOM SR_Cardiac : Yes
DICOM SR_Vascular : Yes
DICOM SR_OB/GYN : Yes
JPEG, WMV, & AVI : Yes
USB : Yes
HDD/SDD : 80GB
DVD/CD RW : Yes