– Kit includes:
– Gc Fujicem Refill Pack 13.3g Cartridge: 1 Cartridge of 13.3 gm / 7.2 ml
– Instruction Manual
– Package Contains:
- GC FujiCEM
– Paste Pak Cartridge 13.3 gm / 7.2 ml, with mixing pad
– The GC Fuji Cem Glass Ionomer Luting Cement mixes into a creamy consistency that will flow readily when seated to a film thickness of just 3 microns
– The GC Fuji Cem luting system consists of replaceable double-barrelled paste cartridges called Paste Pak cartridges that fit into a special paste pak dispenser
– The specially developed Paste Pak System is designed to simplify dispensing and offer greater consistency in cementation helping to ensure a perfect result every time
– Benefits:
- Cartridge delivery always dispenses the correct ratios
– Minimizes cement waste
– Flexibility in the amount of cement that can be dispensed
– Easier mixing in only 10 seconds
– No air bubbles
– Sufficient working time
– Minimal film-thickness of only 3 µ.
– Guaranteed adhesive strength
– Effective fluoride release
– Optimal clinical performance
– The working time from start of mixing is 3 minutes, enough for cementing long span bridges
– After the prosthesis is seated, cement will harden in about within 2 minutes and 30 seconds
– Indications:
– Cementing all types of metal, porcelain fused to metal, and resin crowns, inlays, onlays and bridges
– Cementing porcelain inlays
– As a base or liner
– Directions for Use:
– Paste Pak Cartridge Loading: Make sure that the piston is completely retracted into the dispenser. To retract the piston, hold both the slide block and release lever (on the underside of the dispenser) with fingers and pull them back together. Load the cartridge into the Paste Pak Dispenser. To remove the cartridge, retract the piston fully and turn the cartridge back to the marked positions. After cartridge loading, slide the release lever forward until it stops.
– Dispensing: Remove the cartridge cover. Depress the lever to dispense the required amounts of paste onto the mixing pad. While depressing the lever, level and cut off the extruded material from the tips of the cartridge by moving the cartridge and dispenser to an upright position on the mixing pad. When the lever is released after dispensing, residual pastes at the tips are retracted into the cartridge. Replace the cartridge cover.
– Mixing: After dispensing, incorporate and spread the material out in a thin layer on the mixing pad using a plastic spatula. Mix thoroughly, with lapping strokes, for 10 seconds. Be careful not to incorporate air bubbles.