GE Logiq E9 Ultrasound Machine – Refurbished

MPIN: MP11220

Sign in to view price

Ask for Quote

Overview

Application training for the GE Logiq E9 with XDclear:

KPI’s on-staff sonographer can provide onsite applications training or remote training via video conference at a set price plus travel costs. A pre-recorded video training course is included in the sale, lease or rental of the Logiq E9 from KPI ultrasound.

Logiq E9 Service options:

Free technical support is available from KPI during installation and over the course of the standard limited warranty. Technical support is available after the warranty period at an hourly cost per issue.

GE Logiq E9 Maintenance:

KPI recommends the use of a surGE protector along with a dedicated power outlet. Probes should be disinfected after every use with a disinfectant wipe proven not to damaGE the lens (KPI recommends SonoWipes for this.) One PM visit (preventative maintenance) every year.

Logiq E9 FAQ:

GE Logiq E9 Dimensions & Weight:

Height: (adjustable), (maximum) 1410 mm (55.5 in.), (minimum) 1130mm (44.5 in.)

Width: 585 mm (23 in)

Depth: 830 mm (32.8 in)

Weight: 140 kg (309 lbs.), approx 400 lbs with packaging

Logiq E9 XDclear Specifications:

Digital Beamformer

Displayed Imaging Depth: 0 – 36 cm

Minimum Depth of Field: 0 – 2 cm (Zoom, probe dependent)

Maximum Depth of Field: 0 – 36 cm (probe dependent)

Adjustable Dynamic RanGE

Logiq E9 Electrical power:

VoltaGE 100 – 240 VAC

Frequency 50/60 Hz

Power Consumption maximum of 1.2 KVA with on-board peripherals; 0.7 KVA without peripherals

Revisions

GE Logiq E9 BT09 to BT15 revisions:

GE first launched the Logiq E9 in 2009. That first version was designated as BT09. “BT” is an abbreviation of “Break Through” and the number designates the year in which this version was launched. So the GE Logiq E9 BT09 was launched in 2009 and was in production till the next version in 2010, the Logiq E9 premium BT10. The BT versions are also referred to as a Rev. or revision. The BT09 is Rev 1, BT10 is Rev 2, and so on. Each version fixed bugs in the Logiq E9, improved hardware or software and gave access to new transducers.

The Logiq E9 BT10 is upgradable to BT11. The Logiq E9 BT11 added strain-based elastography, and Elasto QA as an option. BT13 added XDClear as an option along with access to the new C1-6D and C2-9D convex transducers that were made specifically with the new XDClear technology. The Logiq E9 BT13 is also based on a new BEP (back end processor) to improve performance. BT14 again upgraded the BEP and added optional Shear Wave Elastography.

All revisions of the GE Logiq E9:

GE Logiq E9 BT09 (Rev 1)

GE Logiq E9 BT10 (Rev 2)

GE Logiq E9 BT11 (Rev 3)

GE Logiq E9 BT13 (Rev 4)

GE Logiq E9 BT14 (Rev 5)

GE Logiq E9 BT15 (Rev 6) Current version in 2016

Popular configurations of the Logiq E9 in 2016:

  • GE Logiq E9 BT11 with 3 transducers

This is a General imaging (GI) and Women’s health configuration

C1-5D Convex

11L-D Linear

IC5-9D Endocavitary

  • GE Logiq E9 BT13 XDclear with 3 transducers

This is a General imaging (GI) and Women’s health configuration

C1-6D Convex XDclear

11L-D Linear

IC5-9D Endocavitary

  • GE Logiq E9 BT11 with 2 transducers

This is a 4D & OB/GYN configuration

RAB4-8-D 4D Convex

IC5-9D Endocavitary

  • GE Logiq E9 premium BT11 with 2 transducers

This is a Cardio/Vascular configuration

M5S-D Cardiac Sector Matrix

11L-D Linear

Probes

All GE Logiq E9 probes / transducers:

4D Convex RAB6 [ 2 – 8 MHz ] 80° field of view, real-time 4D

4D Convex RAB2-5-D [ 1 – 5 MHz ] 85° field of view, real-time 4D

4D Convex RAB4-8-D [ 2 – 8 MHz ] 90° field of view, real-time 4D

4D Micro-convex RNA5-9-D [ 3 – 10 MHz ] 115° field of view, real-time 4D

4D Intracavitary RNA5-9-D [ 4 – 9 MHz ] 145° field of view, real-time 4D

4D Linear RSP6-16-D [ 6 – 18 MHz ] 38mm field of view, real-time 4D

Convex XDClear C1-6-D [ 1 – 6 MHz ] 80° field of view

Convex XDClear C2-9-D [ 2 – 9 MHz ] 70° field of view

Convex C1-5-D [ 1 – 6 MHz ] 70° field of view

Convex Matrix M6C-D [ 2 – 7 MHz ] 55° field of view

Intracavitary IC5-9-D [ 3 – 10 MHz ] 145° field of view

Linear 9L-D [ 2 – 8 MHz ] 44mm field of view

Linear 11L-D [ 3 – 11 MHz ] 38mm field of view

Linear Matrix ML6-15-D [ 4 – 15 MHz ] 50mm field of view

Intraoperative Linear L8-18i-D [ 4 – 15 MHz ] 25mm field of view

Cardiac sector matrix M4S-D [ 1 – 4 MHz ]

Cardiac Sector 6S-D [ 1 – 5 MHz ] 90° field of view

Sector S1-5-D [ 1 – 6 MHz ] 90° field of view

Cardiac sector matrix M5S-D [ 2 – 8 MHz ] 120° field of view

Pediatric cardiac sector S4-10-D [ 3 – 9 MHz ] 90° field of view

Pencil P2-D [ 2.0 MHz ] CW split crystal

Pencil P6-D [ 6.3 MHz ] CW split crystal

TEE Transesophegeal 6Tc [ 2 – 8 MHz ] 90° field of view

Advanced Logiq E9 probes: 4D and TEE

The Logiq E9 BT13 supports 23 different transducers including the [ 2 – 8 MHz ] 6Tc TEE probe for cardiac applications (though without 4D) and a full range of six volume transducers including the rare [ 3 – 10 MHz ] RNA5-9-D 4d microconvex transducer, and the equally rare [ 6 – 18 MHz ] RSP6-16-D 4d linear transducer. Very few ultrasound machines besides the Logiq E9 support all these probes in one unit. This is a fantastic cost savings for a multi-application clinic or radiology department that can purchase one unit that does the same work as 2 or 3 others. The [ 4 – 15 MHz ] L8-18i-D intraoperative linear is perfect for scanning in the small area within a surgical incision.

Popular GE Logiq E9 transducers:

The [ 1 – 6 MHz ] C1-5-D convex is the most popular convex transducer for the Logiq E9 in general applications because of its versatility and affordable price. The [ 3 – 11 MHz ] 11L-D linear transducer is likewise versatile and able to handle peripheral vascular, abdominal, small parts and MSK imaging. The [ 3 – 10 MHz ] IC5-9-D is the most popular intracavitary transducer for the Logiq E9 balancing affordability with good OB/GYN and Urology imaging.

Features

GE Logiq E9 Standard Features:

19” high resolution LCD monitor with 90°, and fold-down and lock mechanism for transportation

10.4” high resolution LCD touch panel

4 active probe ports

Automatic Optimization

CrossXBeam

SRI HD (Speckle Reduction Imaging)

Fine Angle Steer

Coded Harmonic Imaging

Coded Contrast Imaging

Virtual Convex

Advanced 3D

Raw Data Analysis

Real-time automatic Doppler calculations

OB calculations

Fetal trending

Multigestational calculations

Hip Dysplasia Calculations

Gynecological Calculations

Vascular Calculations

Urological Calculations

Renal Calculations

Cardiac Calculations

InSite ExC capability

TUI

Q-analysis

Auto IMT

Cine Memory: 776 MB, Dual/Quad Image, Review Loop and Speed.

DICOM

Public SR Template

On-board electronic documentation

Integrated 250 GB HDD, with 137 GB for Image Storage

Patient Information database

Image Archive on integrated CD/DVD and hard drive

On-board storage of thermal printer

Integrated locking mechanism for rolling lock and caster swivel lock

Integrated cable management

Front and rear handles

Easily removable air filters

Foot Switch with programmable functionality

Console Protective Cover

GE Logiq E9 technology definitions:

CrossXBeam: Combines several images from different angles into a single, real-time image that allows for improved border definition and high contrast resolution.

SRI-HD: High-definition speckle reduction imaging on the Logiq E9 that increases contrast resolution by reducing speckle noise while maintaining true tissue appearance.

Coded Harmonic Imaging: This improves near-field resolution for clearer small parts imaging and for far field penetration on the Logiq E9.

Coded Contrast Imaging :This enhances the view of the Fallopian tubes vs. other tissue.

TUI:Tomographic ultrasound imaging on the Logiq E9 allows you to view volume data in multiple slices.

Q-Analysis: This plots the velocity information of discrete points for graphical analysis on the Logiq E9.

Auto IMT: Reduces the time it takes to evaluate the carotid artery’s intima-media thickness by automatically detecting the edges of the intima-media.

Accessories

GE Logiq E9 Accessories:

Sony UPD-897MD Digital Black & white thermal printer

Sony UPD-898MD Digital Black & white thermal printer

Sony UPX-898MD Digital Black & white thermal printer

Sony UPD-25MD Digital Color thermal printer

Mitsubishi P95DW Digital Black & white thermal printer

Mitsubishi CP30DW Digital Color thermal printer

Sony DVO-1000 DVD Recorder

CIVCO disposable biopsy guides (for Convex, Linear and Endo-cavity transducers)

Logiq E9 Supplies:

Aquasonic ultrasound gel

Sono ultrasound wipes

Sony UPP-110HG thermal printing paper

Sony UPC-21L color thermal printing pack

Mitsubishi CK30L printing paper

Mitsubishi K95HG high gloss thermal printing paper

Logiq E9 ports:

4 active transducer ports

External USB printer connection

DVI-I output available for compatible devices

S-Video output

Ethernet network connection

Options

GE Logiq E9 Options:

These are features that are not standard on the Logiq E9 BT13 with XDClear, but which can be added to the configuration for an additional cost.

B-Flow

B-Flow Color

CW Doppler

LOGIQView (Extended Field of View)

4D Real Time

VOCAL II

Beta View

Volume Navigation

Scan Assistant

Compare Assistant

Breast Productivity Package

Thyroid Productivity Package

OB Measure Assistant

Breast Measure Assistant

Coded Contrast Imaging

Elastography

Quantitative Flow Analysis

TVI

Stress Echo

Wireless LAN

DICOM 3.0

Physiological input panel

Report writer

Integrated DVD-R Multi Drive

GE Logiq E9 optional technology definitions:

LOGIQView: A type of panoramic imaging on the Logiq E9 that combines images over an extended length of anatomy, improving visualization and giving greater clinical information.

VOCAL II: Volume Calculation on the Logiq E9 that helps evaluate irregular structures by automatically calculating volumes based on a tracing of a region of interest.

Beta View: This allows for the adjustment of the Volume O-Axis position of 3D probes in 2D mode. The green line in the displayed symbol indicates the position ofthe acoustic block. + and – defines the corresponding sweep direction on the Touchscreen.

Volume Navigation: A Logiq E9 technology that combines volume ultrasound with an advanced navigation to overlay real-time ultrasound images with saved CT, MR, PET or other ultrasound images for comparison. It can also be used to do needle guidance, and to visually track your position during an exam and mark points of interest.

Scan Assistant: Automated step by step help for those new to scanning on the Logiq E9.

Compare Assistant: View a patient’s prior and current studies side-by-side during an exam.

OB Measure Assistant: Automatic measurements on the Logiq E9 that can be easily edited or accepted in a click.

Elasto QA Quantitative Analysis (Logiq E9 BT14 option): Elastography in quantitative data as a value to determine the stiffness and elasticity of tissue.

Shear Wave Elastography (Logiq E9 BT14 option) :With the Shear Wave option, the scanner creates distortion by generating shear waves in tissue using a diagnostic ultrasound transducer. Shear waves “push” the tissue at a low frequency in either a single burst of high amplitude, long duration pulses or a series of short pulses. Shear Wave Elastography is superior to the earlier Strain-based Elastography.

Elastography:Elastography shows the spatial distribution of tissue elasticity properties in a region of interest by estimating the strain before and after tissue distortion caused by external or internal forces. The strain estimation is filtered and scaled to provide a smooth presentation when displayed. With Elastography active, the image will show a color map/bar indicating the level of elasticity detected by the system. The Elastography image is achieved by pulsating the probe manually while you are scanning the anatomy of interest.

TVI: Tissue Velocity Imaging on the Logiq E9 measures myocardial velocities longitudinally, evaluating systolic and diastolic function.

Imaging Modes

GE Logiq E9 Imaging Modes:

B-Mode

M-Mode

Color Flow Mode (CFM)

Power Doppler Imaging (PDI)

PW Doppler

3D

Advanced 3D

Anatomical M-Mode

Split Screen

Logiq E9 Optional Imaging Modes:

Extended Field of View (LOGIQView)

Coded Contrast Imaging

Elastography

Real Time 4D

CW Doppler

B-Flow

B-Flow Color

Applications

GE Logiq E9 Applications:

Applications or Apps are the types of exams or studies that an ultrasound machine can do. More than this if an ultrasound machine supports a specific application it will have calculations, measurement and reporting software included to support those apps and make them useful in a clinical environment.

The GE Logiq E9 offers the broadest selection of applications in the GE lineup.

Abdominal

Obstetrical

Gynecological

Breast

Small Parts

Peripheral Vascular

Vascular

Transcranial

Intraoperative

Transrectal

Transvaginal

Transesophageal

Pediatric

Neonatal

Musculoskeletal

Urological

Adult Cardiac

Pediatric Cardiac

Specification

System Overview

Year Launched : 2011
Estimated Market Price ($) : Premium
Monitor (inch) : 19″ LCD
Tilt/Rotate Adjustable Monitor : Yes
Monitor Resolution : 1280*1024
Image Size Resolution :
Touch Screen (Inch) : 10.4″
Trackball or Trackpad : Trackball
CP Back-Lighting : Yes
Weight : 298lbs(135kg)
Probe Ports : 4
Battery : No
Boot-Up Time :
Sleep Mode (Quick Start) :

Maximum Depth of Field : 36cm
Minimum Depth of Field : 0-2cm
Cart (HCU) : No
Independent Steer & Lockable Wheels : Yes

Imaging Modes

2D, M mode : Yes
M-color Flow Mode : Yes
Anatomical M-mode : Yes
Trapezoidal Mode : Yes
Color, Power Angio, Pulse Wave Doppler : Yes
Bi-directional Power (=HD FLOW) : No
SCW Doppler : Yes(Option)
Tissue Doppler(Velocity) Imaging : Yes
Freehand 3D : Yes
Live 3/4D OB/GYN : Yes
HD Live : No
STIC (Spatio-Temporal Image Correlation) : Yes(TUI)
Live 3D Echo : No
Stress Echo : No
Strain and Strain Rate (Cardiac) : Yes(Option)
B Flow : Yes
Panoramic Imaging (=Logiq view) : Yes
Contrast Imaging – Cardiac : Yes(Option)
Contrast Imaging – General Imaging : Yes
Strain-based Elastography : Yes
Shear Wave Elastography : No

Features

Tissue Harmonic Imaging : Yes
Spatial Compounding(=CrossXbeam) : Yes
Speckle Reduction (=SRI) : Yes
Auto Image Opt(B mode) : Yes
Auto Image Opt(Doppler) : Yes
Write Zoom : Yes
Triplex Mode : Yes
Needle Enhancement or Needle Recognition : Yes
Auto NT Measurement (=Sono NT) : No
Auto Follicle 2D Measurement : Yes
Auto Follicle 3D Measurement : No
Auto IMT : Yes
Auto IMT (Real Time) : No
Automated B/M/D Measurement : Yes
Automated LH Measurement(Automated Function Imaging(AFI), Cardiac Motion Quantification(CMQ), or Auto EF(Ejection Fraction) : Yes
Live Dual (B/BC) Mode : Yes
SmartExam or Scan Assistant : Yes
Fusion : Yes
Raw Data File : Yes
Flexible Report : Yes

Barcode Reader : No
Gel Warmer : Yes(BT10)

Applications

Abdominal : Yes
Women’s Health Care (GYN & Breast) : Yes
OB : Yes
Fetal Echo : No
Vascular : Yes
TCD(Transcranial) : Yes
Small Parts (Breast, Thyroid, Testis…) : Yes
MSK/Anesthesiology : Yes
Pediatrics : Yes
Urology (Renal, Prostate…) : Yes
Echocardiography_Adult : Yes
Interventional Cardiology : No
Echocardiography_Pediatric : Yes
Echocardiography_Neonate : Yes
Stress Echocardiography : Yes
Transesophageal Echo_Adult : No
Transesophageal Echo_Pediatric : No
Internal Medicine w/ Shared Service : Yes
Surgury : No
Interventional Radiology : No
Contrast Imaging _ General Imaging (Low MI) : Yes
Contrast Imaging _ Cardiac (High or Low MI) : Yes
Bowel Imaging : No
Strain Elastography : No
Shear Wave Elastography : Yes

Transducers

Convex (1~6Mhz) : Yes(1~5Mhz, on XDclear)
Convex (2~9Mhz) : No
Single Crystal Convex (1~6Mhz) : Yes
Single Crystal Convex (2~9Mhz) : Yes
2D Arrary 3D Convex (1~6Mhz) : No
Micro Convex (5~8Mhz): Yes
Single Crystal Endocavity_Straight Type (3~10Mhz) : No
Endocavity_Curved Type (5~8Mhz) : Yes(5~9Mhz)
3D Convex (2~6Mhz) : Yes(4~8Mhz)
3D Convex Light Weight (2~7Mhz) : No
3D Endocavity (3~10Mhz) : Yes
3D Micro Convex (3~9Mhz) : Yes
3D Linear (4~18Mhz) : Yes
Linear (>14Mhz) : Yes
Linear (3~12Mhz) : Yes
Linear (<9Mhz) : Yes(Mhz)
Single Crystal Linear (>14Mhz) : No
Single Crystal Linear (3~12Mhz) : No
Single Crystal Linear (<9Mhz) : No
Linear 50mm : Yes
Linear 25mm : No
Hockey stick (<13Mhz) : No
Hockey stick (>13Mhz) : No
T or L shape Intra Operative : No
Phased Array_Adult (1~5Mhz) : Yes
Single Crystal Phased Array_Adult (1~5Mhz) : No
2D Arrary 3D Phased Array (1~5Mhz) : No
Phased Array_Pediatric (3~8hz) : Yes
Single Crystal Phased Array_Pediatric (3~8hz) : No
Phased Array_Neonate (4~12Mhz) : Yes
ICE (Intracardiac Echo Cardiography) : No
TEE_Adult (3-7Mhz) : No
TEE_Pediatric (3~7Mhz) : No
2D Array 3D TEE (2~7Mhz) : No
Pencil CW (2Mhz) : Yes
Pencil CW (5 or 6Mhz) : Yes

Connectivity

DICOM 3.0: Yes(Option)
DICOM SR_Cardiac : Yes
DICOM SR_Vascular : Yes
DICOM SR_OB/GYN : Yes
JPEG, WMV, & AVI : Yes
USB : Yes
HDD/SDD : 112GB
DVD/CD RW : Yes
Wireless LAN : Yes(Option)

Shipping Policy

Orders made at Medpick are initiated and processed for shipment upon receipt of request from the customer. Please note that our Shipping Services (Fee, Transportation, Loss or Damage of any shipment, etc.) are in accordance with the Seller\'s terms of Shipment.

Refund Policy

Please refer to Medpick Return Policy.

Cancellation / Return / Exchange Policy

Please refer to Medpick Return Policy.

Recently view product

SHOPPING FOR A BUSINESS?

 

Sign up for Insider Pricing and get access to attractive discounted prices on commercially rated products as well as dedicated Account Representatives to manage your orders.

LOGIN

REGISTER

SHOPPING FOR A BUSINESS?

Sign up for Insider Pricing and get access to attractive discounted prices on commercially rated products as well as dedicated Account Representatives to manage your orders.

 

LOGIN

REGISTER

Ask for Quote

    Enter your Name*


    Enter your Email Id*

    Mobile Number*

    Enter Message*