Advanced Proportional Solenoid Valve (PSOL)-

PSOL based technology ensures faster, safer and accurate gas delivery which also reduces work of breathing and helps in improving synchrony

Active Exhalation Valve

Active exhalation valve system actively controls and maintains the target pressure. It allows unrestricted breathing during both inspiratory and expiratory phases of the breath cycle and vents excess pressure (due to Pressure overshoot, patient coughs). This promotes better patient – ventilator synchrony and potentially decreases the need for sedation

Comprehensive Monitoring

Monitoring of vital signs variables such as mandatory and spontaneous minute ventilation, spontaneous frequency,

exhalation time constant and leaks. Built-in respiratory mechanics menu provides a vital tool for making correct information-based decision, increasing the e¿¿¿¿cacy of treatment and guaranteeing patient safety

Reliable Flow Sensor

Its rugged reusable flow sensor gives exceptional response and accurate monitoring even when used with Nebuliser

Adults And Pediatrics Mode

+VCV – Volume Control (Assisted / Controlled)

+PCV – Pressure Control (Assisted / Controlled)

+PSV – Pressure Support

+CPAP – Continuous Positive Airway Pressure

+SIMV – (VCV) + PSV

+SIMV – (PCV) + PSV

+MMV + PSV – Mandatory Minute Ventilation

+PSV + Tidal Volume Assured

+APRV – Airway Pressure Release Ventilation

+NIV – Non-Invasive Ventilation

Parameter Selection (according to operative mode and patient category)

+Tidal Volume : 20-2500 mL

+Programmable Minute Volume (MMV + +PSV): 1.0-50 L/min

+Resulting Minute Volume: 0.01-130 L/min

+Inspiratory Time: 0.1-10 seconds (30s in APRV)

+I:E Ratio: 5:1- 1:599

+Respiratory Rate:

+ADL/ PED: 1-100 bpm

+FiO : 0.21-1.0 2

+Inspiratory sensitivity:

+Flow Triggered: 0.2-15 L/min

+Pressure Triggered: 0.5-20 cmH O below PEEP 2

+Expiratory sensitivity for PSV: 5%-80% of the initial peak flow, in steps of 5%

+PEEP/CPAP: 0-50 cmH O 2

+Controlled Pressure (PCV): 2-100 cmH O 2

+Support Pressure (PSV): 0-100 cmH O 2

+Inspiratory Pause (programmable in VCV): 0-2 seconds

+Inspiratory Flow Waveform (in VCV): +Rectangular and Descending Ramp

+Inspiratory Flow (resultant): 0.2-180 L/min

+Maximum pressure limited (safety limits): up to 120 cmH O

Pneumatic Gas Supply:

+Oxygen: Pressure 2.8-6 bar (approx 41-87 psi) Connector: DISS 9/16’-18

+External Air: Pressure 2.8-6 bar (approx 41-87 psi) Connector: DISS 3/4″-16 Automatic gas switching when one of them is absent in order to allow patient ventilation with the remaining gas

Warranty and Services provided anywhere in India

Shipping Policy

Orders made at Medpick are initiated and processed for shipment upon receipt of request from the customer. Please note that our Shipping Services (Fee, Transportation, Loss or Damage of any shipment, etc.) are in accordance with the Seller\'s terms of Shipment.

Refund Policy

Please refer to Medpick Return Policy.

Cancellation / Return / Exchange Policy

Please refer to Medpick Return Policy.

Recently view product

SHOPPING FOR A BUSINESS?

 

Sign up for Insider Pricing and get access to attractive discounted prices on commercially rated products as well as dedicated Account Representatives to manage your orders.

LOGIN

REGISTER

SHOPPING FOR A BUSINESS?

Sign up for Insider Pricing and get access to attractive discounted prices on commercially rated products as well as dedicated Account Representatives to manage your orders.

 

LOGIN

REGISTER

Ask for Quote

    Enter your Name*


    Enter your Email Id*

    Mobile Number*

    Enter Message*