Product Details:
Minimum Order Quantity | 1 Unit |
Modes of ventilation | CMV(VC), CMV(PC), AV(PC), AV(VC), SIMV(VC) |
Operation Mode | Electricity Operated |
Patient Age Group | Adult |
Application | Portable, ICU |
Type | Mechanical |
Drager Evita 2 Dura ICU Ventilator (Preused)
Ventilation mode:
- IPPV, IPPVAssist (CMV, CMVAssist)
- SIMV, SIMVASB (SIMV, SIMV/Psupp)
- MMV, MMVASB (MMV, MMV/Psupp)
- BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)
- CPAP, CPAPASB (CPAP, CPAP/Psupp)
- APRV (optional)
- ILV (optional)
- Enhancements
- AutoFlow™ – Automatic adaptation of inspiratory flow in volume controlled modes
- ATC™ – Automatic Tube Compensation (optional)
- IV – Mask Ventilation (optional)
- Adult, Pediatric and Neonatal mode
- Ventilation frequency (f): 0 to 100 /min, 0 to150 /min (Neonatal)
- Tidal volume (VT) (BTPS): §0.1 to 2.0 L (Adult) §0.02 to 0.3 L (Pediatric) §0.003 to 0.1 L (Neonatal) ¡Inspiratory flow: §6 to 120 L/min (Adult) §6 to 30 L/min (Pediatric and Neonatal) ¡Inspiratory pressure: 0 to 80 mbar (cmH2O) ¡PEEP / intermittent PEEP:0 to 35 mbar (cmH2O)
- Pressure assist (PASB) (Psupp):0 to 80 mbar (cmH2O)
- Rise time for inspiratory pressure: 0 to 2 s ¡O2 concentration: 21 to 100 Vol.%
- Multi-sense Trigger Criteria: Internal automatic pressure trigger, Flow, Volume (Flow adjustable 0.3 to 15 L/min)
Measured values displayed
- Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
- Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
- Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTASB (VTPS) (0 to 3999 mL)
- Breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)
- O2 concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
Lung mechanics:
- Resistance ((0.0 to 600 mbar/L/s)(cmH2O/L/s)
- Compliance ((0.0 to 300 mL/mbar)(mL/cmH2O)
- Breathing gas temperature: 18°to 51°C
- Waveforms: Airway pressure-time, flow-time, volume-time, …
- Trends (optional): FiO2, MV, VT, f, PEEPi, R, C, etCO2, …
- Loops (optional): Paw-V, V-Flow, Flow-Paw, …
- Capnography (etCO2) (optional): 0 to 100 mmHg
- CO2 production (VCO2): 0 to 999 mL/min, STPD
- Serial dead space Vds: 0 to 999 mL, BTPS
- Dead space ventilation (Vds/VT): 0 to 99%Alarms / Monitoring
- Airway pressure: High/Low
- Expired minute volume: High/Low
- Tidal volume: High
- Apnea alarm time: 5 to 60 s
- Spontaneous breath frequency: High
- Inspired O2 concentration: High/Low
- Breathing gas temperature: High
- SpO2 pulse (optional): High/Low
- etCO2 (optional): High/Low
Operating data
- Mains power connection: 100 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)
- Power consumption: Approx. 125 W
- Gas supply operating pressure: O2, air: 2.7 to 6 bar/39 to 87 PSI
Physical Specifications
- Dimensions ventilator (WxHxD): 530x290x450 cm (20.9×11.4×17.7 inches) (without trolley)
- Weight basic unit: Approx. 27 kg (60 lbs.)
- Diagonal screen size: 6.5″ TFT LCD color display
Machine outputs
- Digital output: Output and reception via an RS 232 C interface
- Digital output (optional): For output and reception via two RS 232 C interfaces
- Analog output (optional): For analog output of two measured values