Stasis Tablet: Connects to upto 7 beds to create a central monitoring tablet (can be used at the bedside with 1 tablet for each monitor also in high-acuity areas)
Stasis Remote access apps: Shows real-time streams of vitals data,and high resolution vitals trends chart on nursing station desktop, doctors smartphone, central monitoring station desktops, Smart TVs
System Overview
Year Launched : 2017
Regulatory clearences: USFDA-cleared (510k cleared); ISO-3845
Stasis Monitor
Dimensions (cm) : 13.3cm(T) X 10.3cm(W) X 7.2cm(D)
Weight: 2.43lbs(1.1Kg)
Protection: Class II Type CF – Defibrillation Protected
Display Size: 15 cm (6”) diagonal
Network Type: IEEE 802.11 b/g/n & Bluetooth Low Energy
Probe Ports:4 (SpO2, ECG, NIBP, Temperature)
Battery: Yes, rechargeable; 2 hours to full charge
Battery back-up : minimum 5 hours
Vitals: Pulse rate, Pulse oximetry (SpO2), 3-lead ECG, Respiratory rate, Non-invasive Blood pressure, Skin temperature
Stasis Tablet:
Display: 8”-10″ display
Resolution: 1280*800
Tablet Battery: Li-Po 5100 mAh rechargeable
Security: Locked to Stasis software; Physical tablet lock
INTERNATIONAL STANDARDS Regulatory clearences: USFDA-cleared (510k cleared); ISO-3845 Electrical Safety
Meets IEC 60601-1: Medical electrical equipment – Part 1:
General requirements for basic safety and essential performance
Alarm System
Meets IEC 60601-1-8: Medical electrical equipment – Part 1-8:
General requirements for basic safety and essential performance – Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems
Patient Monitoring Safety
Meets IEC 60601-2-49: Medical electrical equipment – Part 2-49:
Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment
Electromagnetic Compatibility
Meets IEC 60601-1-2: Medical electrical equipment – Part 1-2:
General requirements for basic safety and essential performance – Collateral Standard: Electromagnetic disturbances – Requirements and tests
SPO2 Safety, Quality, & Accuracy
Meets IEC 80601-2-61: Medical electrical equipment – Part 2-61:
Particular requirements for basic safety and essential performance of pulse oximeter equipment
NIBP Safety, Quality, & Accuracy
Meets IEC 80601-2-30: Medical electrical equipment – Part 2-30:
Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers
ECG Safety, Quality, & Accuracy
Meets IEC 60601-2-27: Medical electrical equipment – Part 2-27:
Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
TEMP Safety, Quality, & Accuracy
Meets IEC 80601-2-56: Medical electrical equipment – Part 2-56:
Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
Wireless Compatibility
FCC Part 15 Subpart C 15.247, ANSI C63.10- 2013
Dust & Water Resistance
IP22 rating